Type 2 AC surge protection device TRS-A series

  • Graphite gap surge arrester
  • Installtion to main distribution boards
  • For protection against impact of direct or indirect lightning strikes in wide range of applications -houses, office and industrial buildings

The working principle of surge protection device:

The surge arresters commonly defined as SPDs (Surge Protection Devices), are devices designed to protect electric systems and equipment against transient and impulse overvoltages such as those caused by lightning strikes and by electric switching.

Their function is to divert the discharge or impulse current generated by an overvoltage to earth/ground, thereby protecting the equipment downstream.

SPDs are installed in parallel with the electric line to be protected. At the mains rated voltage, they are comparable to an open circuit and have a high impedance at their ends.

In the presence of an overvoltage, this impedance falls to very low values, closing the circuit to earth/ground.

Once the overvoltage has ended, their impedance rises again rapidly to the initial value (very high), returning to open loop conditions.

The first-level lightning protection device can discharge the direct lightning current, or discharge the huge energy conducted when the power transmission line is directly struck by lightning. For places where direct lightning strikes may occur, CLASS-I lightning protection must be carried out.

The TRS-A series type 1 SPDs are available have a impulse current capacity of 15kA, 25KA, 50KA in single-phase or 3-phase configuration and with various voltages in order to protect any type of power supply system.

THOR Type 1 DIN-rail SPD features are offering quick thermal response and perfect cut-off function and providing fast and reliable protection for various power supply systems.And its capacity to safely discharge current with 10/350 μs waveform.

Device Category

Parameter/Type TRS-A15 TRS-A25 TRS-A50
Nominal volatge                                                 Un  230 V AC
Maximum operating voltage                                Uc  275 V AC
Lightning impulse current (10/350 μs)               Iimp 15 kA 25 kA 50 kA
Voltage protection level                                      Up ≤ 2,0 kV ≤ 2,2 kV ≤ 2,5 kV
Insulation resistance group > 100 mΩ
Response time <100ns
Cross-section of connected conductors solid (min/max) 16 mm2 / 35 mm2
Cross-section of connected conductors stranded (min/max) 16 mm2 / 35 mm2
Fault indication
Degree of protection IP20
Range of operating temperatures (min/max) -40℃~+70℃
Humidity range 5%~95%
Mounting DIN rail 35 mm
According to standard EN 61643-11:2012, IEC 61643-11:2011 / T1
Remarks Other Uc can be customized.(420V AC, 385V AC, 320V AC, etc.)